- Uncover the lever of switching and the lever handle, address to the Section Removal and installation of a cover of the lever of switching of transfers/selector.
|
- Pull a slip (1) at first in the direction of an arrow (And) and then take out in the direction of an arrow (In).
|
|
|
At cars with the control panel of the conditioner located over an ashtray it is necessary to extend the panel previously a little. |
|
- Turn out fastening bolts (C) and take out an ashtray (2) of the central console.
|
- Take out the damping washer (1) and a damper of noise (2) up.
|
|
- Turn out bolts of fastening of a cover (an arrow on an accompanying illustration).
|
|
- Measure distance (and) between two carving fingers in the switching drive.
|
|
|
It is necessary to measure between centers fingers. |
|
- The distance has to be and = 85 mm. If the received value differs from specified, adjust distance (and) as follows: Weaken the screw (shooter) of fastening of the pushing bar. The pushing bar has to move easily to both parties behind in the switching drive on the ram.
|
- Adjust the size (and) by shift of the pushing bar behind. Tighten a bolt of fastening of the pushing bar the moment 25nm.
|
- Weaken a bolt (the shooter on an accompanying illustration) in the switching drive. Connection pushing the bar/drive of switching has to have the easy course.
|
|
- Install the switching lever: The lever has to be centered below in a spherical support. The distance from a spherical support to the switching lever below from all directions has to be identical.
|
|
- Install the lever vertically in the direction of the movement and hold it in this situation.
|
- Tighten a bolt of fastening of a bar of switching the moment 25nm.
|
|
- Tighten bolts of fastening of a cover of protection against noise the moment 10nm. Watch the provision of installation: The arrow on a cover specifies in the direction "forward".
|
|
- The inclusion button with the fixing mechanism: Install the button together with a switching lever cover on the lever and turn a connecting element against the stop.
- The inclusion button with a tightening collar: Install the inclusion button by a snovy collar on the lever of switching and squeeze a collar flat-nose pliers.
- If necessary, install the control unit of the conditioner and an ashtray.
|